CJD Plug Standard — GX16-4

This document defines the single connector standard for buildings (Domus): a GX16-4 (“aviation”) threaded connector. It is used on garage walls and service panels to deliver 24 V DC power and a simple status/ID signal to vehicles and devices.

Scope: buildings and fixed infrastructure only. Vehicle-side wiring is covered in the Robulus docs.


1) Electrical Specification

  • System Voltage: 24 V DC (nominal), tolerance ±10%
  • Maximum Current (continuous): 15 A (class limits may be lower)
  • Connector Type: GX16-4 (4-pin)
  • Ingress Protection: IP55+ when fully assembled (panel gasket + mated plug)
  • Default State: Power OFF upstream until status/ID check passes

Recommended protections (upstream of the socket):

  • eFuse/current-limit set to site rating (≤ 15 A)
  • TVS diodes on power and signal lines (24 V system)
  • Over-temperature/over-current cut-off
  • Ground-fault protection per city electrical code

2) Mechanical Standard

  • Panel Socket (female): GX16-4, panel-mount
  • Mounting Location: Exterior garage/service wall, 40–60 cm above ground
  • Thread Diameter: 16 mm (GX16 standard); panel cutout Ø16 mm
  • Fixation: Threaded bushing + lock nut (supplied with socket)
  • Key Notch Orientation: 12:00 (upwards) — enforce during installation
  • Cable Entry (plug side): Strain relief clamp or PG gland
  • Materials: Nickel-plated brass shell, dielectric insert, tin-plated contacts

Robotic integration: If a robot arm performs coupling, it must support a rotating grip with ≥ 1 N·m torque to screw/unscrew the coupling nut.


3) Pin Assignment

Pins are numbered clockwise when viewing the socket (female) face-on, with the key notch at 12:00.

Pin #NameDirectionDescription
1+24V DCOutPositive power line
2GNDGround / negative
3STATUSI/ODigital line for presence check or ID
4RESVReserved (future use)

STATUS line (baseline behavior):

  • Logic level 3.3 V tolerant (accepts 3.3–5 V input from controller)
  • Default pull-up in the building controller (10–47 kΩ)
  • Presence detect = vehicle side pulls low on plug-in (open-drain recommended)
  • Optional: 1-Wire™/UART-based ID in future revisions (keep pin free of heavy noise)

4) Cable & Wiring

Building side (panel → controller):

  • Power pair:2.5 mm² (AWG 14) copper for 15 A runs up to 10 m
  • Signal pair: 0.22–0.5 mm² (AWG 24–20) twisted (optional), shield to GND at controller
  • Insulation: ≥ 60 V rating, 105 °C preferred (silicone or XLPE)
  • Keep power & signal separated where practical; avoid parallel runs with high-current AC

Vehicle/device side (plug):

  • Use a molded or metal-shell GX16-4 plug (male) with strain relief
  • Keep STATUS wiring away from ESC/PWM lines; add 100 Ω series + 100 nF to GND near MCU if noisy

5) Installation Procedure (Panel Socket)

  1. Cutout: Drill/cut Ø16 mm hole; deburr.
  2. Gasket: Fit IP gasket between socket flange and panel.
  3. Orient: Align key notch to 12:00.
  4. Fix: Insert socket, tighten lock nut (snug; do not deform panel).
  5. Wire: Crimp or solder pigtails; observe pin numbers (see table).
  6. Protect: Route to controller via gland/conduit; add eFuse/TVS upstream.
  7. Label: Apply pinout sticker within 10 cm of socket; mark circuit rating (e.g., “24 V DC / 15 A”).
  8. Test: Perform continuity and polarity checks before energizing.

6) Commissioning & Tests

  • Continuity/Polarity: Verify Pin-1 = +24 V, Pin-2 = GND (with supply OFF first).
  • STATUS check: Plug in a test dongle that pulls STATUS low → controller should arm relay/enable power.
  • Load test: Apply 75% rated load for 10 min; ensure < 30 °C rise at contacts and no voltage sag > 10%.
  • Ingress: Spray test at low pressure; inspect for moisture ingress.
  • Disconnect safety: Power must drop within < 50 ms after unscrew/disconnect (controller rule).

7) Safety Notes

  • Never exceed 15 A continuous on a single GX16-4 connector.
  • Do not hot-plug under heavy load; controller must disable power until STATUS passes.
  • Ensure proper strain relief; avoid sharp cable bends at the plug entry.
  • Use only connectors with intact seals and undamaged threads.

8) Bill of Materials (reference)

  • GX16-4 Panel Socket (female), IP-gasketed, nut included
  • GX16-4 Cable Plug (male) with strain relief
  • Panel IP gasket (NBR or silicone)
  • eFuse/current limiter (programmable or fixed, ≤ 15 A)
  • TVS diodes (24 V power line + signal line)
  • Label “24 V DC / 15 A — CJD GX16-4” + pinout diagram

9) Marking

  • Near each socket:
    CJD GX16-4 | 24 V DC | Max 15 A | Pins: 1=+24V, 2=GND, 3=STATUS, 4=RESV
  • Optional QR linking to this spec.

10) Revision History

  • v3.0 — Baseline GX16-4 standard; status line defined; IP55+ requirement; 12:00 notch orientation.

Civitas Juvantia Digitalis